How do I implement barcode keyed automation with NRGship for UPS?
NRGship UPS Pro and UPS for FileMaker both support barcode keyed automation for orders that have been imported and contain a value for the Reference 1 field.
Scanned materials should include the Reference 1 field value using a barcode symbology like Code 128. These can be created using barcode fonts, or thru FileMaker modules like Barcode Basics.
Scanner configurations are outlined below - or consult your scanner manual for proper configuration.
Symbol LS2208 - MACMac setup is for Apple-1, Apple-2 for pre/post-scan
- Set USB keystroke delay to LONG (40 msec) p7-9
- Set scan options (enter) p13-4
- Set scan data transmission to prefix-data-suffix p13-5
- Set scan transmission (enter) p13-5
- Set scan prefix to GUI 1 (GUI key 3049) p13-4
- Set scan suffix 1 to GUI 2 (GUI key 3050) p13-4
[get numberic scans from Appendix D]
Symbol DS6608 - MAC
Mac setup is for Apple-1, Apple-2 for pre/post-scan
- Set USB keystroke delay to LONG (40 msec) p8-7
- Set scan data transmission to prefix-data-suffix 1 p14-6
- Set scan prefix to GUI 1 (GUI key 3049) p14-4
- Set scan suffix 1 to GUI 2 (GUI key 3050) p14-4
[get numberic scans from Appendix D]
Symbol LS2208 - WINDOWS
Windows setup is for CTRL-2, CTRL-6 for pre/post-scan
- Set USB keystroke delay to LONG (40 msec) p7-9
- Set scan options (enter) p13-4
- Set scan data transmission to prefix-data-suffix p13-5
- Set scan transmission (enter) p13-5
- Set scan prefix to GUI 1 (GUI key 1000) p13-4
- Set scan suffix 1 to GUI 2 (GUI key 1030) p13-4
[get numberic scans from Appendix D]
Symbol DS6608 - WINDOWS
Windows setup is for CTRL-2, CTRL-6 for pre/post-scan
- Set USB keystroke delay to LONG (40 msec) p8-7
- Set scan data transmission to prefix-data-suffix 1 p14-6
- Set scan prefix to GUI 1 (GUI key 1000) p14-4
- Set scan suffix 1 to GUI 2 (GUI key 1030) p14-4
[get numberic scans from Appendix D]
Symbol DS3478 Wireless - WINDOWS
Windows setup is for CTRL-2, CTRL-6 for pre/post-scan
- set USB keystroke delay to LONG (40 msec) p8-7
- set scan data transmission to prefix-data-suffix 1 p14-6
- Set scan prefix to CTRL-2 (GUI key 1000) p14-4
- Set scan suffix 1 to CTRL-6 (GUI key 1030) p14-4
[get numberic scans from Appendix D]
Symbol LS4071 Wireless - WINDOWS
Windows setup is for CTRL-2, CTRL-6 for pre/post-scan
- set pause duration to "04" (40 msec) p5-76
- set scan options p5-78
- set scan data transmission to prefix-data-suffix p5-79
- set scan transmission (enter) p5-79
- Set scan prefix to CTRL-2 (GUI key 1000) p5-77
- Set scan suffix to CTRL-6 (GUI key 1030) p5-77
[get numberic scans from p5-98]